The seal is the interface that makes a floating roof work. A deck can be perfectly buoyant and still lose product if the gap between its edge and the shell is not closed reliably. This article explains the seal families used on internal floating roofs, what the rules require and why the details of fitting and maintenance decide the result.
Under 40 CFR 60.112b, a fixed-roof tank with an internal floating roof must use one of three closure arrangements between the wall and the deck edge: a foam- or liquid-filled seal mounted in contact with the liquid, two seals mounted one above the other with both continuous, or a mechanical shoe seal in which a metal sheet is held against the wall by springs or weighted levers and connected to the deck by a fabric envelope.
That list is a regulatory minimum for a defined class of tanks, not a statement that one arrangement is always best. The choice depends on the product, the shell condition, the emission target and the maintenance approach.
A mechanical shoe seal tolerates some shell deviation because the shoe follows the wall; a liquid-mounted seal removes the vapour space beneath the seal face. Understanding which mechanism is in play makes it much easier to diagnose a leak.
A primary seal is the first closure. A secondary seal sits above it, either rim-mounted or shoe-mounted, and reduces the vapour that escapes past the primary. A technical discussion of AP-42 methodology notes that secondary seals cut rim loss by roughly sixty to eighty percent compared with a primary-only arrangement, with the shoe-mounted secondary more effective but mechanically more complex.
State in the specification whether the secondary is included, its mounting arrangement and the acceptance test. A quotation that includes only a primary seal is not equivalent to one with both, even if the deck and pontoons are identical.
Where a jurisdiction requires a secondary seal, confirm the current wording and the permitted configurations before the order is placed.
A seal is designed to tolerate a degree of shell out-of-roundness, but it cannot follow an unlimited deviation. The tank shell expands hydrostatically and can be distorted by settlement, so the gap between the deck edge and the wall changes with level and with temperature.
Inspection guidance for API 653-based programmes tells inspectors to look for wear, tears and gaps against the shell, and notes that seal design is one reason shell tolerances matter. A new seal fitted to a badly distorted shell will wear at the same sectors as the old one.
Measure roundness before specifying the seal profile, and price corrective work as a separate scope if it is needed.
AP-42 Chapter 7 Section 7.1 treats storage tank emissions as several paths: rim seal, withdrawal, deck fittings and deck seam. Rim seal loss is driven by wind and by the vapour pressure of the product, and the seal's condition and type determine how much escapes.
A technical summary of the methodology notes that the exponent in the rim-loss equation reflects whether the seal is wind-dominated or leakage-dominated, which is a formal way of saying that exposed vapor-mounted seals and well-fitted mechanical shoe seals behave differently.
Fit leakage can rival rim loss. The same summary lists K values for fittings and notes that a single open slotted gauge well can equal many gasketed access hatches. A seal programme that ignores fittings is therefore incomplete.
The federal rule cited here is specific about openings: covers and lids must remain closed with no visible gap except when in use, bleeder vents must be gasketed, rim space vents must be gasketed and set correctly, sample wells need a fabric cover over at least ninety percent of the opening, and column and ladder penetrations need a sleeve or sliding cover.
State rules can be tighter. The Louisiana implementation plan referenced in this series describes liquid-mounted, mechanical shoe and double-seal arrangements and sets out requirements for projections below the liquid and gasketed covers.
Treat these as the functional specification of the sealing system, not as paperwork. Each item corresponds to a place where vapour could leave the tank.
Start with product compatibility. A seal compound that swells, shrinks or hardens will fail early whatever the design, so ask for compatibility data against the specific product and temperature. Select the primary and secondary arrangement against the emission target and the shell condition.
Fit seals late in installation, against the real shell, and verify continuous contact around the full circumference. After any repair, recheck contact; a local fix can create a hard spot that lifts the seal elsewhere.
Monitor seal condition as a measured task: gap, wear, hardness and contact are more useful than a general impression of condition. No internal floating roof project is held in the verified project library, so no seal life is claimed here; the method is attributed to the named sources.
The compound at the seal face is chosen by chemistry, not by habit. EPDM, nitrile, polyurethane and PTFE-based materials behave differently in aromatic and paraffinic products, and temperature moves the boundaries. A selection guide lists the wrong seal material as one of the common causes of floating roof problems.
Ask the supplier for compatibility data against the specific product and operating temperature, and record the compound in the component register. When a tank changes service, that record is the first thing to review.
A seal that has hardened, swollen or shrunk should be treated as a material failure, not merely as wear. Replacing it with the same compound will repeat the outcome.
Seal condition should be measured rather than described. Record gap at marked positions, note wear and hardness, and check contact around the full circumference after any adjustment or repair.
Under the federal requirements cited here, covers and vents must remain closed and gasketed and sample wells must be largely covered. Inspect those features alongside the rim, because fitting leakage can rival rim leakage in the AP-42 inventory.
No internal floating roof project is held in the verified project library, so no seal life or gap result is claimed here; the methods are attributed to the named sources.
A seal gap that appears at one sector is usually telling you about the shell rather than the seal. Before replacing the seal, check roundness at that location and compare it with the installation survey.
If the shell has moved, a new seal will reproduce the same gap. Correct the cause or specify a seal with enough travel for the actual condition.
Standardising seal types across similar tanks reduces spares and training, but only where the products and shell conditions are genuinely comparable. A seal that is common on the site is not automatically compatible with every product.
Keep the compatibility record with the spare, not in a separate document.
Where an air rule applies, seal condition is not only a maintenance matter. Keep gap measurements, repair records and replacement dates in the compliance file so the inspection history supports the operating claim.
A seal that has been replaced with a different compound should be recorded as a change, because compatibility and lifetime may differ from the original.
No internal floating roof project is held in the verified project library; this is a record-keeping method, not a reported installation.
Arrangement | Description | Typical consideration |
Liquid-mounted | Foam or liquid-filled seal at the liquid | Removes space under seal face |
Double seal | Two continuous seals stacked | Lower may be vapour-mounted |
Mechanical shoe | Metal shoe held to shell, fabric envelope | Tolerates shell deviation |
Secondary | Rim- or shoe-mounted above primary | Further reduces rim loss |
The arrangements in this table are the ones described in the cited regulation and technical sources; the right one follows your product and shell condition.
Evidence note: this sealing-system guide is an engineering explanation, not a project record. The verified project library contains no internal floating roof delivery, so no installed seal, gap measurement or emission result is claimed here; the seal arrangements and limits are drawn from the cited rule and technical sources.
A sealing system is more than a ring of material: it is a primary closure, often a secondary closure, compatible compounds and a shell the seal can follow. Size and specify the seal against the product and the actual tank geometry, keep deck fittings closed and gasketed, and treat seal condition as a measured maintenance item rather than a visual impression.
Q: What is a primary seal?
A: The first closure between the floating deck edge and the tank wall. Common forms are liquid-mounted foam or liquid-filled seals and mechanical shoe seals.
Q: What does a secondary seal add?
A: A second closure above the primary seal, mounted on the rim or shoe, which further reduces vapour escape. Many volatile services require or prefer it.
Q: What does 40 CFR 60.112b require for IFR seals?
A: One of three closure devices: a liquid-mounted seal, two stacked continuous seals, or a mechanical shoe seal, with defined requirements for openings and covers.
Q: Why do seals need shell roundness control?
A: The seal follows the deck as it moves. A shell that is out of round changes the gap around the circumference and can break contact at some sectors.
Q: Do deck fittings matter as much as the rim seal?
A: Often yes. An AP-42-based analysis notes that an open slotted gauge well can equal many gasketed hatches in loss, so fitting control is part of seal performance.
Q: How much can a secondary seal reduce rim loss?
A: A technical discussion citing AP-42 methodology puts the reduction at roughly sixty to eighty percent against a primary-only arrangement; confirm the basis for your service.
Center Enamel is the trading name of Shijiazhuang Zhengzhong Technology Co., Ltd, established in 2008 and based in Shijiazhuang, Hebei Province, China. The company manufactures glass-fused-to-steel bolted tanks, fusion-bonded epoxy coated tanks, stainless steel and welded steel tanks, pressure vessels, aluminium geodesic dome roofs and floating roof systems. Aluminium dome design work is carried out against AWWA D108, API 650, ADM 2015, ASCE 7-10 and IBC 2012, and the broader product range is covered by ISO 9001, NSF/ANSI 61, CE/EN 1090, ISO 28765, WRAS and FM approvals. The company reports 30,000 installed projects and an annual output of 300,000 enamel steel plates, with technical support delivered through an international distributor network and a stated 24-hour response commitment.
If your project involves tank roofs, floating decks or the shells that carry them, send the tank diameter, shell height, product, operating temperature and site design loads. We will return a preliminary structural concept, the applicable design code basis, and a written scope that separates what is included from what the site contractor must provide.